1.Main functions of the equipment
(1) Suitable for shearing various low-carbon steel plates, household scrap steel, scrapped cars, scrapped shipboards, industrial flower plates and non-ferrous metals, etc.
(2) Each moving part is hydraulically driven, with stable operation, high shearing pressure and high shearing efficiency. The working pressure of the hydraulic system is ≤25MPa;
(3) PLC control operation is simple, convenient, safe and reliable;
(4) The equipment has a three-phase backup power of 38OV, bOHz, GOHz (optional).
2.Main technical parameters of the equipment
| 1 | Shearing cylinder | Cylinder model | YG 340/250 | |||
| Nominal pressure | 254T×2 units | |||||
| 2 | Pressure cylinder | Cylinder model | YG 180/120 | |||
| Nominal pressure | 71T×2 units | |||||
| 3 | Optional | Hydraulic motor | Model | JMDG16-1600B | ||
| Push cylinder | Cylinder model | YG 180/120 | ||||
| Nominal pressure | 71T×1units | |||||
| 4 | Material box size
(length x width x height) |
6000×1500×700 mm | ||||
| 5 | Cut width | 1600 mm | ||||
| 6 | Cut material size | 500mm | ||||
| 7 | Cut frequency (theoretical) | 3 times/min | ||||
| 8 | Maximum cut size | 600/865mm | ||||
| 9 | Theoretical design pressure | 28 Mpa | ||||
| 10 | Actual working pressure | 21-25 Mpa | ||||
| 11 | Power required by the main motor of the equipment | 110KW x 1units =110KW | ||||
| 12 | Power supply standard | 380/3 phase 50Hz | ||||
| 13 | Motor | Model | MSJ-ZMVT-360L | Power | 110KW | |
| Speed | 2200 rpm | Quantity | 1 units | |||
| 14 | Hydraulic pump | Model | HLKSOV 280 | Rated pressure | 31.5 MPa | |
| Rated flow | 280ml/rev | Quantity | 2 units | |||
| 15 | Cooling | Optional (□ water cooling, □ air cooling, □ air conditioning refrigeration) | ||||
3. Working conditions of the machine
(1) Power supply: three-phase AC, voltage 3SOV (± 10%), frequency (optional) bOHz, GOHz (± zO/o);
(2) Working medium: L-HM46 or L-HM68 anti-wear hydraulic oil;
(3) Altitude below ⒛∞ meters;
(4) Ambient temperature: △0℃ to dong℃;
(5) Humidity: When the ambient temperature is ±⒛℃, the relative humidity shall not exceed gO%; when the ambient temperature is ±dong℃, the relative humidity shall not exceed 50%.