1.Main functions of the equipment
(1) Suitable for cutting all kinds of low carbon steel plate, scrap steel, scrap cars, scrap ship plates, industrial flower plates and non-ferrous metals, etc.
(2) All moving parts are hydraulically driven, with stable work, large shear pressure and high shear efficiency. The working pressure of the hydraulic system is less than 25MPa;
(3) PLC control operation is simple, convenient, safe and reliable;
(4) Three-phase power supply 380V,50Hz, 60Hz (optional).
2.Main technical parameters of the equipment
1 | Shearing cylinder | Cylinder model | YG 450/320 | Quantity | 3 units | ||
Nominal pressure | 445T×3units | Itinerary | 1160mm | ||||
2 | Pressure cylinder | Cylinder model | YG 320/250 | Quantity | 2 units | ||
Nominal pressure | 225T×2units | Itinerary | 1300 mm | ||||
3 | Optional | Hydraulic motor | Model | JMDG16-2400B | Quantity | 1units | |
Push cylinder | Cylinder model | YG 220/160 | Quantity | 1 units | |||
Nominal pressure | 106T×1units | Itinerary | 7850 mm | ||||
4 | Material box size
(length x width x height) |
8000×2400×1200 mm | |||||
5 | Cut width | 2500 mm | |||||
6 | Cut frequency (theoretical) | 3 times/min | |||||
7 | Maximum cut size | 733/1130mm | |||||
8 | Theoretical design pressure | 28 Mpa | |||||
9 | Actual working pressure | 21-25 Mpa | |||||
10 | Required power of main motor of equipment | 90KW x 3 units=270KW(Add fast filling valve) | |||||
11 | Power supply standard | 380/3 phase 50Hz | |||||
12 | Motor | Model | MSJ-ZMVT-360M | power | 90KW | ||
Speed | 2200 rpm | Quantity | 3 units | ||||
13 | Hydraulic pump | Model number | HLKSOV 260 | Rated pressure | 31.5 MPa | ||
Rated flow | 260 ml/rev | Quantity | 6 | ||||
14 | Cooling | Optional (□ water cooling, □ air cooling, □ air conditioning) |
3. Working conditions of the machine
(1) Power supply: three-phase AC, voltage 380V (± 10%), frequency (optional) 50Hz, 60Hz (± zO/O);
(2) Working medium: L-HM46 or L-HM68 anti-wear hydraulic oil;
(3) Altitude below 2500 meters;
(4) Ambient temperature △0℃ to 40℃;
(5) Humidity: When the ambient temperature is ±⒛℃, the relative humidity shall not exceed gO‰; when the ambient temperature is ±佣℃, the relative humidity shall not exceed
50%.